mos fet relays g3vm-401g 215 mos fet relays g3vm-401g analog-switching mos fet relays in 400-v load voltage series ? 4-pin sop package in the 400-v load voltage series. ? continuous load current of 120 ma. ? dielectric strength of 1,500 vrms between i/o. ? rohs compliant. application examples ? broadband systems ? measurement devices and data loggers ? amusement machines note: the actual product is marked differently from the image shown here. list of models dimensions note: all units are in millimeter s unless otherwise indicated. terminal arrangement/internal connections (top view) actual mounting pad dimensions (recommended value, top view) contact form terminals load voltage (peak value) model number per stick number per tape spst-no surface-mounting terminals 400 vac g3vm-401g 100 --- g3vm-401g(tr) --- 2,500 4.4 0.25 3.9 0.2 0.4 0.1 2.54 0.25 2.1 max. 0.1 0.1 7.0 0.4 0.6 0.3 0.15 g3vm-401g note: the actual product is marked differently from the image shown here. weight: 0.1 g 43 12 g3vm-401g 6 to 6.3 1.2 0.8 2.54 g3vm-401g
216 mos fet relays g3vm-401g absolute maximum ratings (ta = 25 c) electrical characteristics (ta = 25 c) recommended operating conditions use the g3vm under the following conditions so that the relay will operate properly. item symbol rating unit measurement conditions input led forward current i f 50 ma repetitive peak led forward current i fp 1 a 100 s pulses, 100 pps led forward current reduction rate i f / c ? 0.5 ma/ ct a 25 c led reverse voltage v r 5v connection temperature t j 125 c output load voltage (ac peak/dc) v off 400 v continuous load current i o 120 ma on current reduction rate i on / c ? 1.2 ma/ ct a 25 c dielectric strength between input and output (see note 1.) v i-o 1,500 v rms ac for 1 min operating temperature t a ? 40 to +85 c with no icing or condensation storage temperature t stg ? 55 to +125 c with no icing or condensation soldering temperature (10 s) --- 260 c 10 s note: 1. the dielectric strength between the input and output was checked by applying voltage be- tween all pins as a group on the led side and all pins as a group on the light-receiving side. item symbol mini- mum typical maxi- mum unit measurement conditions input led forward voltage v f 1.0 1.15 1.3 v i f = 10 ma reverse current i r --- --- 10 av r = 5 v capacity between terminals c t --- 30 --- pf v = 0, f = 1 mhz trigger led forward current i ft --- 1 3 ma i o = 120 ma output maximum resistance with output on r on --- 17 35 i f = 5 ma, i o = 120 ma current leakage when the relay is open i leak --- 0.003 1.0 av off = 400 v capacity between terminals c off --- 70 --- pf v = 0, f = 1mhz capacity between i/o terminals c i-o --- 0.8 --- pf f = 1 mhz, v s = 0 v insulation resistance r i-o 1,000 --- --- m v i-o = 500 vdc, r oh 60% tu r n - o n t i m e t on --- 0.3 1 ms i f = 5 ma, r l = 200 , v dd = 20 v (see note 2.) turn-off time t off --- 0.1 1 ms v out i f t on t off 10% 90% i f 1 2 4 3 r l v dd v out note: 2. turn-on and turn-off times item symbol minimum typical maximum unit load voltage (ac peak/dc) v dd --- --- 320 v operating led forward current i f 57.525ma continuous load current (ac peak/dc) i o --- --- 120 ma operating temperature t a ? 20 --- 65 c
mos fet relays g3vm-401g 217 engineering data led forward current vs. ambient temperature i f - ta continuous load current vs. ambient temperature i o - ta led forward current vs. led forward voltage i f - v f led forward current i f (ma) continuous load current i o (ma) led forward current i f (ma) ambient temperature ta (
) ambient temperature ta
led forward voltage v f (v) continuous load current vs. on-state voltage i o - v on on-state resistance vs. ambient temperature r on - ta trigger led forward current vs. ambient temperature i ft - ta continuous load current i o (ma) on-state resistance r on ( ) trigger led forward current i ft (ma) on-state voltage v on (v ) ambient temperature ta (
) ambient temperature ta (
) turn on, turn off time vs. led forward current t on , t off - i f turn on, turn off time vs. ambient temperature t on , t off - ta current leakage vs. ambient temperature i leak - ta turn on, turn off time t on , t off (s) turn on, turn off time t on , t off (s) current leakage i leak (na) led forward current i f (ma) ambient temperature ta (
ambient temperature ta (
) 0 ? 20 60 20 40 80 100 120 100 80 60 40 20 0 0 ? 20 280 120 100 80 60 40 20 0 240 200 160 120 80 40 ta = 25c 0.6 0.8 1 1.2 1.6 1.8 1.4 100 30 50 10 3 5 1 0.3 0.5 0.1 ta = 25c i f = 5 ma ? 3 ? 2 ? 1 0 2 3 1 200 ? 200 ? 100 0 100 i o = 120 ma i f = 5 ma 30 0 ? 20 0 20 40 80 100 60 10 20 40 60 50 i o = 120 ma t < 1 s 0 ? 40 5 100 80 60 40 20 0 ? 20 4 3 2 1 30 1 2000 100 ta = 25c v dd = 20 v, r l = 200 t on t off 1000 300 500 100 50 30 50 10 3 5 v dd = 20 v, r l = 200 i f = 5 ma 0 ? 40 1000 100 80 60 40 20 0 ? 20 800 600 400 200 t on t off v off = 400 v ? 20 0 20 40 80 100 60 1000 300 500 100 30 50 10 3 5 1
mos fet relays g3vm-401g omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. x302-e-1 printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 12/10 specificat ions subject to change without notice all sales are subject to omron electronic components llc standard terms and conditions of sale, which can be found at http://www.components.omron.com/compon ents/web/webfiles.ns f/sales_terms.html all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.0393 7. to convert grams into ounces, multiply by 0.03527.
|